Complete Acoustic Solutions for Data Center Construction

For Developers · Contractors · Municipalities · Corporations

Exterior Perimeter Barriers · Interior Ceiling Systems
Noise Compliance · Security · Privacy · Future Value
Proven. Certified. Built for the Long Term.

53STC
47OITC
0.90NRC
RIVERBANK LABS · TL26-262 (STC/OITC) · A26-364 (NRC)
Aerial rendering of a Walls of Troy data center campus with perimeter noise barriers — conceptual illustration
Conceptual AI-generated rendering for illustrative purposes

thewallsoftroy.com  |  800-987-3306  |  Brunswick, GA  |  U.S. Patent 5,661,723

The Low-Frequency Threat — Invisible, Inescapable, and Unhealthy

Data center HVAC systems generate 31.5 Hz – 250 Hz energy that travels through walls, floors, and bodies.

Why Low Frequency Is the Real Danger

31.5 – 80 Hz — Infrasound Zone

Below the threshold of clear hearing but fully felt by the body. Resonates in chest cavities, ear canals, and skulls. The WHO classifies sustained exposure as a health risk causing sleep disruption, anxiety, and cardiovascular stress.

80 – 160 Hz — Chest Resonance Zone

Matches the natural resonance frequencies of the human thorax. Prolonged exposure causes fatigue, cognitive impairment, and has been linked to reduced immune response in animal studies.

160 – 250 Hz — Low Tonal Hum Zone

The frequency range most commonly reported by data center neighbors. Concrete walls reflect it rather than absorb it. Standard STC testing begins at 125 Hz — missing the worst bands entirely.

Animals are affected too. Livestock, wildlife, and companion animals in proximity to unshielded data centers show elevated stress markers, reduced reproductive rates, and behavioral disruption. Low-frequency industrial noise is not a nuisance — it is a documented biological hazard.

Walls of Troy™ Transmission Loss — Low-Frequency Range

TL26-262 Data · 31.5 Hz – 250 Hz

253035404550553431.535403350376336804110043125411604220045250

Walls of Troy™ Absorption — Low-Frequency Range

A26-364 Data · 31.5 Hz – 250 Hz

-0.10.00.20.431.540506380100125160200250

Low-frequency data: TL26-262 & A26-364 · Riverbank Acoustical Laboratories  |  Troy Acoustics Corporation

Data Center Campus Construction — Complete Troy Acoustics Solution

Walls of Troy noise barrier — Bayamón, Puerto Rico
Noise Barrier — Bayamón, Puerto Rico
⚠ Why Noise Planning Cannot Be an Afterthought

Data centers built without acoustic planning face permit denials, costly retrofits, community lawsuits, and worker health liability.

Troy System Capabilities
Applications:
New construction · Retrofit · Campus expansion · Any US jurisdiction
Exterior:
Walls of Troy™ wall: NRC 0.90 · STC 53 · OITC 47 · 22'+ heights
Interior:
Troy ceiling system: CAC 38 · NRC 1.0 · ASTM E1414-16 certified
Compliance:
FHWA NAC · HUD 24 CFR 51 · EPA Noise Act · OSHA 29 CFR 1910.95 · All 50 States
Security:
Solid mass-wall: zero line of sight · impenetrable perimeter · privacy
Certifications:
UL723 Class A Fire · ASTM G21 Anti-Fungal · ASTM E2180 Anti-Microbial
Life Cycle:
30+ year service life · zero maintenance · asset value protection
Lab Tests:
Riverbank Labs NVLAP 100227-0 · TL26-262 · A26-364 (2026, Preliminary)

Troy Acoustics Corporation  |  troyacoustics.com  |  800-987-3306

Data Center Noise Sources — Why Every Campus Needs Acoustic Planning

Closed-Loop Cooling Systems
85–95 dB(A)

Primary continuous noise source. High-speed fans run 24/7, projecting 31–250 Hz drone horizontally toward adjacent properties day and night.

Backup Power Generators
90–105 dB(A)

Diesel gensets required for redundancy. Weekly NFPA 110 load testing — consistently the #1 community complaint at data center approvals nationwide.

Cooling Tower & AHU Exhaust
70–85 dB(A)

Rooftop AHUs and cooling tower fans direct broadband low-frequency noise horizontally toward surrounding agricultural and residential properties.

Transformer & Electrical Hum
55–80 dB(A)

120 Hz tonal hum from power transformers. Under most state codes a −10 dB tonal penalty applies — making compliance significantly stricter.

The 3 dB Rule — How Data Center HVAC Systems Add Up

Each 500-ton chiller generates ~90 dB(A). Adding a second identical chiller adds exactly +3 dB — making it 93 dB(A). This is because decibels are logarithmic: doubling identical noise sources always adds exactly 3 dB, never doubles the level. A typical campus with 4 chillers reaches ~96 dB(A). Add cooling towers, AHUs, and generators simultaneously and the combined plant total reaches 100–105 dB(A) — far above OSHA action levels and community limits. The low-frequency component of this noise (31–250 Hz) is the hardest to block and the most harmful to human health.

901 chiller932 chillers953 chillers964 chillers

The Walls of Troy Corporation  |  thewallsoftroy.com  |  800-987-3306

The Solution:

Walls of Troy™ Highway Sound Barrier Adapted for Data Centers

Proven on American highways. Now purpose-built for data center perimeter noise control.

U.S. Patent 5,661,723  |  Since 1993

Walls of Troy highway sound barrier panel, Puerto Rico Highway Authority
Puerto Rico Highway Authority panel
NRC 0.90

Noise Reduction Coefficient

SAA = 0.87 · Riverbank Labs A26-364
Tested 2026-07-02 · ASTM C423

STC 53

Sound Transmission Class

Riverbank Labs TL26-262
Tested 2026-06-26 · ASTM E90 / E413
41 dB TL at 100 Hz · 64 dB at 4–5 kHz
Preliminary — final certification pending

OITC 47

Outdoor-Indoor Transmission Class

Riverbank Labs TL26-262
ASTM E1332 · Low-frequency exterior standard

Riverbank Labs TL26-262 (STC/OITC) · A26-364 (NRC)

STC vs. OITC — Two Ratings That Tell the Complete Story

Plain-Language Definitions for Engineers, Developers & Regulators · Riverbank Acoustical Laboratories · NVLAP 100227-0

STC 53  —  Sound Transmission Class

STC measures how much a barrier reduces airborne sound passing through it, tested at frequencies from 125 Hz to 4,000 Hz — the range of human speech, music, and most mechanical equipment noise. An STC 53 rating means a 90 dB noise source on one side is reduced to approximately 37 dB on the other — near inaudibility for most people. STC was originally designed for interior construction, so it starts at 125 Hz — just above the deep industrial hum that data center equipment generates. Troy Fastlane STC 53 is among the highest ratings achieved by any modular sound wall system.

Freq. range: 125 Hz – 4,000 Hz  |  Walls of Troy STC 53  |  TL26-262 2026
  • Industry standard required by most building codes
  • At STC 53: loud sounds nearly inaudible next door
  • Meets or exceeds every US federal & state code
OITC 47  —  Outdoor-Indoor Transmission Class

OITC was developed specifically to measure a barrier's performance against the heavy low-frequency noise that comes from outside — transportation, aircraft, and industrial equipment. Unlike STC, OITC starts at 80 Hz and mathematically weights low frequencies more heavily in the rating calculation. Data center HVAC equipment — chillers, cooling towers, compressors, generators — generates exactly this profile of low-frequency industrial drone starting at 31.5 Hz. OITC 47 is the most relevant and demanding rating for real-world data center compliance because it captures the frequency bands that travel farthest, penetrate conventional walls, and cause documented health effects in humans and animals.

Freq. range: 80 Hz – 4,000 Hz  |  Troy Fastlane: OITC 47  |  TL26-262
  • Designed for EXTERIOR low-frequency industrial noise
  • Starts at 80 Hz — captures the HVAC danger zone
  • The real-world data center compliance standard
Why Both Ratings Matter: STC 53 confirms the wall meets every code at every standard frequency. OITC 47 proves it tames the deep low-frequency HUM that travels farthest, penetrates conventional barriers, and causes documented health harm to humans and animals. Walls of Troy is certified at both.
ASTM E413 (STC)  |  ASTM E1332 (OITC)  |  ASTM C423 (NRC)  |  Riverbank Labs NVLAP 100227-0  |  TL26-262 / A26-364  |  Troy Acoustics

Certified Acoustic Performance — 2026 Riverbank Laboratory Data

Riverbank Acoustical Laboratories · TL26-262 (STC 53 / OITC 47) · A26-364 (NRC 0.90 / SAA 0.87)

Sound Absorption Coefficient by Frequency  (NRC 0.90 / SAA 0.87) — A26-364

00.20.40.60.811.21.41001251602002503154005006308001k1.25k1.6k2k2.5k3.15k4k5k

Sound Transmission Loss by Frequency  (STC 53 / OITC 47) — TL26-262

3035404550556065701001251602002503154005006308001k1.25k1.6k2k2.5k3.15k4k5k
NRC 0.90

SAA = 0.87 · A26-364
Tested 2026-07-02 · Preliminary
Absorbs HVAC broadband noise

STC 53

41 dB TL at 100 Hz · 64 dB at 4 kHz
TL26-262 · Tested 2026-06-26
Blocks at every code-regulated frequency

OITC 47

TL26-262 · ASTM E1332 · Preliminary
Low-frequency industrial noise rating
The real-world data center standard

Troy Acoustics Corporation  |  troyacoustics.com  |  800-987-3306

OITC 47 — Outdoor-Indoor Transmission Class — Low-Frequency Authority

Riverbank Acoustical Laboratories  TL26-262 · ASTM E1332 · NVLAP Lab Code 100227-0 · Tested 2026-06-26

OITC: Reference Noise Spectrum vs. Troy Fastlane™ TL — TL26-262

2535455565758595105801001251602002503154005006308001k1.25k1.6k2k2.5k3.15k4k
Reference Sound Spectrum (dB) Troy Fastlane™ Transmission Loss (dB)
OITC = 47
ASTM E1332 · TL26-262 · 2026
TL26-262 OITC Data
Freq (Hz)Ref Spec (dB)TL (dB)
8010336
10010241
12510143
1609841
2009742
2509545
3159443
4009347
5009350
6309150
8009048
10008952
12508958
16008859
20008859
25008761
31508563
40008464
Walls of Troy Corporation  |  thewallsoftroy.com  |  800-987-3306

Noise Compliance — Federal & State Standards Every Data Center Must Meet

EPA · FHWA · OSHA · HUD · State Property-Line Codes · Troy System Exceeds All Limits

The Compliance Reality: Every US data center faces layered federal, state, and local noise standards from day one. Troy's exterior + interior system meets or exceeds every applicable standard at every octave band — now and for the future.
StandardRequirementTroy PerformanceResult
FHWA NAC Cat. B 67 dB(A) Leq residential STC 53 · NRC 0.90
53 dB TL + absorption
Exceeds
HUD 24 CFR Part 51 45 dB(A) interior
65 dB(A) exterior
STC 53 exterior
CAC 38 + NRC 1.0 interior
Exceeds
EPA Community Noise 55 dB(A) day
45 dB(A) night (outdoor)
OITC 47 / STC 53
25–40 dB beyond limits
Exceeds
OSHA 29 CFR 1910.95 85 dB(A) TWA 8-hr action CAC 38 · NRC 1.0
Cuts server hall reverb
Exceeds
State Property-Line
(All 50 States)
45–80 dB by octave band
Class B receiving land
Troy TL: 41–64 dB/band
NRC 0.90 + OITC 47
Exceeds All
Local Zoning / CUP Typically 50–65 dB(A)
at property boundary
15–35 dB additional
margin above limits
Full Margin
FHWA NAC · HUD 24 CFR Part 51 · EPA Noise Control Act · OSHA 29 CFR 1910.95 · All 50 State Codes  |  Troy Acoustics Corporation

Data Center Interior Acoustics — Worker Safety & the Troy Ceiling Solution

Troy fiber cement suspended ceiling panels installed in a data center interior — CAC-181107
Troy fiber cement ceiling panel — CAC-181107
⚠ OSHA Hazard — 29 CFR 1910.95
Noise-Induced Hearing Loss in Data Centers
90–96dB(A)
85dB TWA
4 hrlimit
The Troy Interior Ceiling Solution
CAC38
Ceiling Attenuation Class
USG Test CAC-181107
NRC1.0
Noise Reduction Coefficient
Maximum absorption

Stops Noise Flanking Between Rooms

CAC 38 prevents server noise from migrating through shared ceiling plenums into offices, control rooms, and adjacent IT halls.

Reduces dB(A) Exposure — OSHA Compliance

NRC 1.0 absorbs virtually all sound energy, slashing reverberation time inside server halls and lowering sustained worker exposure.

Drop-In Suspended Tile — New Build & Retrofit

1″ fiber cement panels drop into standard 15/16″ DXL exposed tee grid. 6″ mineral wool above. No structural work required.

NVLAP Lab Certified

USG Test TROYC-100118 · CAC-181107 · ASTM E1414-16 · NVLAP Lab 200132-0. Independent third-party verification.

USG Test TROYC-100118 · CAC-181107 · ASTM E1414-16 · NVLAP Lab 200132-0  |  Troy Acoustics Corporation

Third-Party Certifications — Critical for Data Center Use

Fire Safety
UL723 — Underwriters Laboratory
Certificate #20180302-R27255
Confirmed October 2025, UL Solutions
  • Flame Spread Index: 0
  • Smoke Developed Index: 0
  • Class A — highest UL fire classification
  • Critical for data center campus permitting
  • No toxic gases emitted under combustion
Anti-Fungal
ASTM G21 — Accugen Laboratories
Lab Report #175034 · June 2021
  • Rating: 0 (zero growth) at 7, 14, 21 & 28 days
  • Tested: Aspergillus, Penicillium, Chaetomium, Trichoderma & Aureobasidium
  • 28-day controlled humidity exposure
  • No degradation of acoustic performance
Anti-Microbial
ASTM E2180 — Accugen Laboratories
Lab Report #175035 · June 2021
  • 99.9999% reduction vs. S. aureus
  • ≥99.9999% reduction vs. K. pneumoniae
  • 7-log reduction in 24 hours contact time
  • Critical for high-density equipment areas
  • Approved by T. Naqvi, M.S. Microbiology
Troy Acoustics Corporation  |  troyacoustics.com  |  800-987-3306

Panel Composition & Structural Specifications

Troy Board panel cross-section — machined flutes, wood fiber layers, concrete base (A26-364)
Cross-section: machined flutes / wood fiber layers / concrete base — A26-364
Troy Board™ Material Composition

60% Portland Cement · 39.5% Wood Fiber (Wood Wool) · 0.5% Sodium Silicate Binder

Zero VOC · Zero flame spread (UL723) · Insoluble in water · Non-toxic · 30+ year service life

Walls of Troy™ Panel Dimensions & 2026 Acoustic Specs
Troy Board Dimensions
4″ × 47¾″ × 11′-3″
Panel Dimensions
7¾″ × 60″ W × 11′-9″ L
Panel Weight (8′ length)
1,300 lbs · 41.2 lbs/sq ft
Panel Weight (4.5′ × 12′)
2,225 lbs per panel
Available Wall Heights
Up to 22′+ using steel W-post system
Concrete Spec (Structural)
3,000 psi · Rebar fy ≥ 40 ksi
Post Embed Plates
3/8″ steel · (2) ½″ dia. × 4″ headed studs
NRC / SAA Rating
0.90 / 0.87 · A26-364 · 2026
STC Rating
53 · TL26-262 · 2026
OITC Rating
47 · TL26-262 · ASTM E1332 · 2026
Walls of Troy Corporation  |  thewallsoftroy.com  |  800-987-3306

Competitive Comparison — Sound Barrier Options for Data Centers

Performance Criterion Walls of Troy™
2026
Concrete Wall
(Reflective)
Fiberglass
Panel
Timber / Wood
NRC (Sound Absorption)✓ 0.90✗ ~0.02⚠ ~0.35⚠ ~0.10
STC (Transmission Block)✓ 53⚠ 45–55✗ 25–35✗ 20–30
OITC (Low-Freq Exterior)✓ 47⚠ ~38–45✗ 18–26✗ 14–22
Low-Freq (31–250 Hz) Health✓ Absorbed✗ Reflected✗ Marginal✗ None
EPA/OSHA/State Compliant✓ Yes⚠ Reflective⚠ Marginal✗ No
Tonal Noise Margin (−10 dB)✓ Large✗ None⚠ Small✗ None
UL723 Class A Fire Rating✓ Yes✓ N/A⚠ Varies✗ Class C
Anti-Fungal (ASTM G21)✓ Yes✓ Inherent✗ No✗ No
Anti-Microbial (ASTM E2180)✓ Yes✗ No✗ No✗ No
Modular / Adj. Height✓ Yes✗ Difficult✓ Yes✓ Yes
Long-term Maintenance✓ Minimal✓ Low⚠ Moderate✗ High

✓ Meets/Exceeds   ⚠ Partial/Variable   ✗ Does Not Meet  |  Troy data: TL26-262 / A26-364 2026

Troy Acoustics  |  troyacoustics.com

Beyond Acoustics — Security, Privacy & Long-Term Asset Value

Physical Security

Troy's 22′+ solid Portland cement-wood fiber panels in structural steel H-beam posts form an impenetrable perimeter. This wall cannot be breached, cut, or climbed.

Complete Privacy

Troy's solid mass-wall provides total privacy — no sight lines, no visual surveillance, no photography of equipment or operations from adjacent properties.

Zero Line of Sight

No adjacent property has any direct visual access to the campus. Staff movements, deliveries, and facility configurations remain completely screened.

The Future Value Argument — Today's Remote Site Is Tomorrow's Neighborhood

Growth Is Inevitable

Every data center built in a 'remote' zone in the last 20 years is now surrounded by development. Low-frequency hum that was acceptable then triggers lawsuits now. Plan from day one.

Barrier Value Multiplies Over Time

When residential neighbors arrive, stricter Class A noise limits apply. The Troy wall — already installed and compliant — protects against costly retrofits and legal challenges.

Permanent Security & Privacy Infrastructure

As the campus scales, the Troy perimeter wall becomes a permanent, low-maintenance security asset protecting sensitive infrastructure from a growing surrounding population.

Property Value Protection

A fully enclosed, acoustically-treated, visually screened perimeter enhances the data center's property value. The Troy wall is a long-term investment, not a cost of construction.

Troy Acoustics Corporation  |  troyacoustics.com  |  800-987-3306

The Troy Acoustics System

Complete Acoustic Solutions for Data Center Construction

For Developers · Contractors · Municipalities · Corporations · Nationwide

800-987-3306  |  818-376-8490
info@troyacoustics.com
www.thewallsoftroy.com
2580 Sidney Lanier Drive, Brunswick, GA 31525
Request a Project Acoustic Consultation
Troy Acoustics · U.S. Patent 5,661,723 · UL723 Class A · STC 53 · OITC 47 · NRC 0.90 · CAC 38 · ASTM G21 · ASTM E2180 · Riverbank Labs 2026